Preparation
Provide protection for pedestrians, vehicles, roofing andfoliage. Test all other non-masonry surfaces for negativereactions and provide protection where required. Remove allloose materials from the surface prior to application. Protectall surrounding areas from possible damage due to spillage ordrippage during application. All projects should start with atest application to determine suitability of the material for thechosen project, method of application and dwell time.
Dilution and Coverage
Dilution: Product is used undiluted.
Coverage: Dependent upon substrate and other conditions.
Application
This product is not for general coatings removal use. It should not be used in inhabited structures.
Application of this product should be done with natural fiber brush or cloth. This material will attack many types of plastic including some synthetic fibers used in paint brushes. Let dwell 10 – 15 minutes and rinse with pressure washer or scrape loosened paint and rinse with water.
Flammable Liquid (Contains Dimethyl Carbonate) The flash point of this material is 60°F. This means that dangerous accumulations of flammable or explosive vapors can be created under normal usage conditions. Do not store nor use near fire of flame. Keep away from potential ignition sources. Solvent soaked rags present a fire hazard. Do not use in confined spaces. Provide mechanical ventilation and/or respirator with organic vapor cartridge.
Skin penetration potential (Contains N-methyl 2-pyrrolidone) This solvent can penetrate the skin faster than most others commonly used. This means that the solvent and whatever is dissolved in it can enter the bloodstream via skin contact. User must wear solvent proof rubber gloves at all times. Do not use to remove chemicals from skin or clothing.